Oil & gas → / GRP Access for Onshore Oil & Gas
Onshore GRP access.
Built around the plant.
Bring pumps, separators, tanks and service routes into one coordinated access plan. Vital develops GRP platforms, walkways and crossings around the operating task, the supporting structure and the conditions at your facility.
Locate your requirement
Choose an area.
Explore the access solution.
Hover over a numbered marker to see the area name, or select it to open the application. On a phone, tap a marker or choose the same numbered area from the list below.
Pump maintenance
Reach operating and maintenance points without compromising equipment removal.
Explore pump maintenance →Pipe crossings
Create a purposeful crossing and a usable position for valve operation.
Explore pipe crossings →Separator access
Reach operating and maintenance points without compromising equipment removal.
Explore separator access →Controls and service covers
Coordinate the access requirement with the surrounding structure, services and maintenance task.
Explore controls and service covers →Tank bund access
Connect inspection points while preserving containment and service access.
Explore tank bund access →Cooling plant access
Coordinate the access requirement with the surrounding structure, services and maintenance task.
Explore cooling plant access →Define the interfaces.
Then develop the system.
An onshore access package often connects assets installed at different times. The route must work around pipework, bund walls, cable routes and equipment-removal spaces. Survey those interfaces before selecting panel spans or fixing positions.
Show the valves, instruments and maintenance points people must reach. Include tools, parts and the clear area needed to work.
Identify the slab, plinths or retained steelwork. Confirm condition, bearing, anchor selection and any project-specific pull-test requirements.
Record chemicals, concentrations, temperature, cleaning fluids and standing water. Coordinate the route with drainage and bund containment.
Agree isolations, delivery access, lifting limits and whether the assembly needs to arrive as identified modules.
Evidence for the actual location
Match the specification
to the operating conditions.
For hazardous areas, the site team’s DSEAR assessment and area classification inform the material and installation requirements. COMAH duties may also apply to the establishment. Neither is a blanket product approval for GRP.
HSE guidance on DSEAR →Bring the applicable requirements
Include the asset-owner specification, loading and deflection criteria, exposure information and required acceptance records. Where access standards are specified, identify the edition and the parts relevant to the assembly.
Agree the evidence for panels, supports, connections and guarding together. Keep product data linked to the installed arrangement.
Technical assurance →Coordinate the package.
Plan the installation.
New platforms can be coordinated with prepared concrete and planned service routes. Refurbishment needs a different starting point: retained steelwork, uncertain substrates, operational restrictions and a safe sequence for removing the old floor.
Capture the asset
Combine drawings with a verified survey of supports, services and access. Record assumptions before dimensions are released.
Survey support →Resolve the assembly
Coordinate panel boundaries, connections, guarding and removable areas. Agree the drawing revision and module sizes before fabrication.
Design coordination →Release for use
Plan installation, inspection and handover. Record the permitted use, retained interfaces and any outstanding items.
Operating-site installation →Explore the working area
Take the next design decision.

Pump & Separator Maintenance Platforms
Reach operating and maintenance points without compromising equipment removal.
Explore the application →
Pipe Crossings & Valve Access
Create a purposeful crossing and a usable position for valve operation.
Explore the application →
Tank Bund Walkways
Connect inspection points while preserving containment and service access.
Explore the application →Connected system choices
Develop the complete access arrangement.
Platforms & walkways
Explore the system options and the information needed to define the assembly.
Platforms & walkways →GRP grating & flooring
Explore the system options and the information needed to define the assembly.
GRP grating & flooring →Stairs & landings
Explore the system options and the information needed to define the assembly.
Stairs & landings →Before you specify.
Can we replace only part of an existing steel walkway?
Yes, the package can be scoped around a defined replacement area. Survey its boundaries, check the retained support structure and agree how adjacent access remains managed during the work.
Does the platform need separate foundations?
That depends on the loads and available structure. Record whether it will bear on existing concrete, new bases, steelwork or ground; the foundation and connection design follows from those inputs.
Start with your asset
Send your drawings.
Define the access package.
Send a marked-up plant layout, photographs of the support structure and the tasks to be carried out. We can then discuss the access arrangement, survey gaps and fabrication or installation scope.