Vital GRP how-to video
How to Cut GRP Grating Around Services
Watch the 2 minute 11 second guide to setting out, supporting and cutting GRP grating around services. Read the episode transcript below.
Read the episode transcript
A service opening may look like a simple cut. But if the support layout, dust controls or final cut are wrong, the floor and the people around it can be put at risk.
Begin with the approved drawing and project RAMS. Confirm the service position, finished size and any allowance for insulation or lagging. Check the support arrangement beneath before marking or cutting anything.
Never cut, move or remove a perimeter or internal support without authorisation. If a service clashes with the design, stop and report it. The support or opening may need to be redesigned before work continues.
Establish the exclusion zones required by the RAMS, including any affected level above or below. Wear the specified site PPE, eye and hearing protection, cover exposed skin and use face-fit respiratory protection where required. Connect effective extraction before cutting begins.
Mark the opening precisely and check it twice. Retain the structural ligament, edge bearing and trimming arrangement required by the approved project design. If the proposed cut differs from that design, stop and obtain a revised detail before continuing.
Use a suitable carbide-tipped GRP blade with dust extraction. Keep the tool controlled and follow the marked line. For a large opening, divide the waste into manageable sections rather than trying to remove one heavy piece.
Before completing the final edge, support or tether the cutout so it cannot drop into the void. Keep hands clear of the blade and maintain control until the section is safely removed.
Remove dust and waste using the approved method. Inspect the remaining grating, every cut edge and the supporting framework. Confirm there are no unsupported edges, damaged bars or changes from the approved arrangement.
Accurate set-out, controlled cutting and continuous support protect the performance of the complete GRP floor. Always work to the current approved drawing and RAMS. For project-specific guidance, speak to Vital GRP.
About this video
This video covers set-out, support, dust control, controlled cutting and inspection when forming service openings in GRP grating.
Read the full technical guide →

Leave a Reply