+44 (0)1206 396446 Call +44 (0)1206 396446

Vital GRP how-to video

How to Cut GRP Grating Around Services

Watch the 2 minute 11 second guide to setting out, supporting and cutting GRP grating around services. Read the episode transcript below.

Read the episode transcript

A service opening may look like a simple cut. But if the support layout, dust controls or final cut are wrong, the floor and the people around it can be put at risk.

Begin with the approved drawing and project RAMS. Confirm the service position, finished size and any allowance for insulation or lagging. Check the support arrangement beneath before marking or cutting anything.

Never cut, move or remove a perimeter or internal support without authorisation. If a service clashes with the design, stop and report it. The support or opening may need to be redesigned before work continues.

Establish the exclusion zones required by the RAMS, including any affected level above or below. Wear the specified site PPE, eye and hearing protection, cover exposed skin and use face-fit respiratory protection where required. Connect effective extraction before cutting begins.

Mark the opening precisely and check it twice. Retain the structural ligament, edge bearing and trimming arrangement required by the approved project design. If the proposed cut differs from that design, stop and obtain a revised detail before continuing.

Use a suitable carbide-tipped GRP blade with dust extraction. Keep the tool controlled and follow the marked line. For a large opening, divide the waste into manageable sections rather than trying to remove one heavy piece.

Before completing the final edge, support or tether the cutout so it cannot drop into the void. Keep hands clear of the blade and maintain control until the section is safely removed.

Remove dust and waste using the approved method. Inspect the remaining grating, every cut edge and the supporting framework. Confirm there are no unsupported edges, damaged bars or changes from the approved arrangement.

Accurate set-out, controlled cutting and continuous support protect the performance of the complete GRP floor. Always work to the current approved drawing and RAMS. For project-specific guidance, speak to Vital GRP.

About this video

This video covers set-out, support, dust control, controlled cutting and inspection when forming service openings in GRP grating.

Read the full technical guide →

Planning a GRP access project?

Discuss your service-opening review →

Leave a Reply

Your email address will not be published. Required fields are marked *

Technical project enquiry

Send the drawings.Show us the constraint.

Share whatever is available. A finished specification is not required; photographs, marked-up PDFs and partial dimensions can all help us identify the next responsible step.

  • Up to five drawings or photographs
  • Project and technical enquiries
  • Reviewed by the Vital GRP team

Tell us what you know

← Back

Thank you. Your enquiry has been received.

The Vital GRP team will review the information you have sent and contact you about the next step. For a time-critical requirement, call 01206 396446. Keep a copy of your drawings and brief for reference. There is no need to send the same enquiry again. If you need to add anything, please contact the team and mention your project.

Drag and drop or click to select up to 5 files, maximum 20 MB per file. Use PDF drawings, JPG or PNG photographs, or Word documents. For DWG, IFC or larger files, contact the team to agree a transfer method. You can send an enquiry without attachments.

Your files are used to review and respond to this enquiry. Open the full contact page.