Engineering evidence · Pultruded GRP connections
Connections in Pultruded GRP: Bolts, Plates, Bearing and Local Effects
Connections are often the governing part of a pultruded GRP structure. The member may carry longitudinal load efficiently, yet the joint introduces bearing, transverse tension, shear, splitting, local bending and deformation around holes. A bolt schedule alone is not a connection design.

Why metal intuition can mislead
Steel connections can rely on ductility, yielding and load redistribution in ways that may not be appropriate for pultruded composites. GRP is directional, and local damage can be sensitive to hole quality, edge distance, clamping and force direction. The design should use a method and product data suited to composite profiles.
The fact that a bolt fits through two profiles does not show how the joint will transfer load.
Map the force path through the joint
Start with the actions entering and leaving the connection: shear, axial force, moment, torsion, uplift and temporary erection loads. Then identify where plates bear, where bolts introduce load, which faces are restrained and whether eccentricity adds local bending.
| Detail | Potential design issue |
|---|---|
| Bolt and hole | Bearing stress, clearance, hole quality and local deformation |
| Edge distance | Splitting or breakout towards a free edge |
| Pitch and gauge | Interaction between adjacent fasteners and load sharing |
| Washer or plate | Clamping area and through-thickness pressure |
| Cleat geometry | Eccentricity, prying and local flange or web bending |
| Member end | Load introduction, trimming and unrestrained local elements |
| Mixed materials | Environmental compatibility and differential movement |
Bearing area needs definition
The contact area between bolt, washer, plate and profile should reflect the actual detail. Oversized washers or spreader plates may distribute clamping force, but their geometry and stiffness must be coordinated. They should not be added as an unexplained generic cure for an overloaded joint.
Hole quality is structural quality
Drilling can affect the local composite, so hole diameter, location, tooling, edge condition and inspection matter. Site drilling near profile ends or existing holes should not be improvised. Drawings should provide enough dimensional control to maintain approved edge distances and avoid clashes.
- Use a drilling method suitable for the profile and required finish.
- Support the component and control breakout during fabrication.
- Keep holes clear of damaged, notched or poorly supported edges.
- Inspect deviations before assembly rather than forcing alignment.
- Treat additional site holes as a design change.
Tightening is not simply “as tight as possible”
Bolts need enough restraint for their intended function without crushing or damaging the profile. The selected bolt, washer, plate and tightening procedure should work as one detail. Where locking arrangements are required, specify them without relying on excessive clamping force.
Connection stiffness affects the frame
A calculation may idealise a joint as pinned, semi-rigid or restrained. The fabrication detail must support that assumption. Frame sway, bracing forces and member moments can change when joint behaviour differs from the model.
Design for assembly and inspection
A technically adequate connection can still fail the buildability test if tools cannot reach it, plates cannot be inserted or bolts are hidden behind plant. Access, tolerances, module sequence and future inspection should be reviewed on the coordinated model or drawings.
Evidence and standards
BS EN 13706 can support specification of pultruded profiles and their declared properties. The connection design still needs an accepted engineering basis, suitable data and project-specific checks. BS 4592 or BS EN ISO 14122 may apply to adjacent flooring and access elements, but they do not validate the joint automatically.
Vital GRP develops joint details alongside member selection and fabrication planning so the connection that is calculated can also be manufactured, installed and inspected.
General guidance only. Structural design, material properties, connections, supports, exposure and applicable standards must be confirmed for each project by the responsible designer.

Leave a Reply